000 01919aab a2200229 4500
008 240115b1990 |||mr||| |||| 00| 0 eng d
022 _a0017-9310
100 _aYou, S.M.
_9788724
100 _aSimon, T.W.
_9788725
100 _aBar-Cohen, A.
_9814021
100 _aTong, W.
_9865661
245 _aExperimental Investigation of Nucleate Boiling Incipience with a Highly-Wetting Dielectric Fluid (R-113)
300 _a105-117 p.
520 _aExperiments on pool boiling heat transfer in saturated R-113 at 1 atm pressure are conducted to investigate anomalies associated with the initiation of boiling using horizontal, 0.13 mm diameter chromel wires and a 0.51 mm diameter, platinum thin-film heater. Wall incipience superheat values of up to 73°C and wide variations in incipience superheats (more than 20°C) from case to case for nominally identical cases are observed. Presentation of incipience superheat results in terms of probability distributions is therefore recommended. The significant influence of the minimum heat flux and corresponding minimum wall superheat (after the cool-down portion of one run and the beginning of the subsequent run) on the incipience superheat excursion is observed. Tests with large step changes in heat flux, using a thin-film. cylindrical heater, indicated increases in incipience superheat of as much as 20% over tests with a series of incremental steps in heat flux up to the same heat flux level.
650 _aNucleate Boiling Incipience
_9879840
650 _aHighly-Wetting Dielectric Fluid (R-113)
_9879841
650 _aPool Boiling Heat Transfer
_9879842
650 _aSaturated R-113
_9879843
773 0 _x00179310
_tInternational Journal of Heat and Mass Transfer
_dNew York, U.S.A : Pergamon Subsidiary of Elsevier Science & Technology
856 _uhttps://www.sciencedirect.com/science/article/pii/001793109090145K
942 _2ddc
_n0
_cART
_o14993
_pMr. Muhammad Rafique Al Haj Rajab Ali (Late)
999 _c814703
_d814703