Custom cover image
Custom cover image

Experimental Investigation of Nucleate Boiling Incipience with a Highly-Wetting Dielectric Fluid (R-113)

By: Material type: ArticleArticleDescription: 105-117 pISSN:
  • 0017-9310
Subject(s): Online resources: In: International Journal of Heat and Mass TransferSummary: Experiments on pool boiling heat transfer in saturated R-113 at 1 atm pressure are conducted to investigate anomalies associated with the initiation of boiling using horizontal, 0.13 mm diameter chromel wires and a 0.51 mm diameter, platinum thin-film heater. Wall incipience superheat values of up to 73°C and wide variations in incipience superheats (more than 20°C) from case to case for nominally identical cases are observed. Presentation of incipience superheat results in terms of probability distributions is therefore recommended. The significant influence of the minimum heat flux and corresponding minimum wall superheat (after the cool-down portion of one run and the beginning of the subsequent run) on the incipience superheat excursion is observed. Tests with large step changes in heat flux, using a thin-film. cylindrical heater, indicated increases in incipience superheat of as much as 20% over tests with a series of incremental steps in heat flux up to the same heat flux level.
Holdings
Item type Current library Call number Vol info Status Date due Barcode
Articles Articles Periodical Section Vol.33, No.1 (January 1990) Available

Experiments on pool boiling heat transfer in saturated R-113 at 1 atm pressure are conducted to investigate anomalies associated with the initiation of boiling using horizontal, 0.13 mm diameter chromel wires and a 0.51 mm diameter, platinum thin-film heater. Wall incipience superheat values of up to 73°C and wide variations in incipience superheats (more than 20°C) from case to case for nominally identical cases are observed. Presentation of incipience superheat results in terms of probability distributions is therefore recommended. The significant influence of the minimum heat flux and corresponding minimum wall superheat (after the cool-down portion of one run and the beginning of the subsequent run) on the incipience superheat excursion is observed. Tests with large step changes in heat flux, using a thin-film. cylindrical heater, indicated increases in incipience superheat of as much as 20% over tests with a series of incremental steps in heat flux up to the same heat flux level.

Visit counter For Websites

Copyright © 
Engr Abul Kalam Library, NEDUET, 2024